Medical devices, healthcare technology and the business of care
FDA RECALL RECORD · Z-0524-2025

Fusion Pro 24, Model 17000 Recall

Fusion Pro 24, Model 17000

FDA recall Class II

Ongoing

FDA lists this Class II recall for Fusion Pro 24, Model 17000. Review the affected identifiers, reported reason and manufacturer instructions below.

Recall at a glance

Recall number
Z-0524-2025
Recall classification
Class II
Enforcement status
Ongoing
Initiation date
Aug 8, 2024
FDA report date
Dec 11, 2024
Quantity in commerce
751
Distribution
See key details
FDA cause
Radiation Control for Health and Safety Act

What is being recalled?

Fusion Pro 24, Model 17000

Affected model & UDI checker

Search the exact identifiers published for Z-0524-2025.

The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.

Affected products

Model / catalog numberProductLot scope reportedUDI / GTIN
17000Fusion Pro 24, Model 17000Check source noticeNot specified
FDA code information

Model 17000 Product Report Accession Number: 2021046-000

View the original FDA recall notice

Why was this product recalled?

a. A small number of Fusion Pro 24 units were released with an incorrectly placed Interlock device. As a result, the system can be operated with the front-loading door in an open position. b. Fails to comply with Class 2 designation, indicated in Part 6 of Laser Product Report. An incorrectly placed Interlock device can allow Class 4 laser radiation fields during operation.

What actions did Epilog Laser Corp. take?

The measures to be taken to repair such defect or to bring the product into compliance with the Federal standard. This Recall provides corrections by repair to a defective safety interlock location by a kit with comprehensive instructions, offered at no cost to purchasers

Read the manufacturer action recorded by FDA

Recall timeline

  1. Recall initiated by firm

  2. FDA notice posted

  3. FDA classification recorded

  4. FDA enforcement report date

Related FDA submissions

No submission number with an exact verified relationship is linked in the retrieved recall notice.

FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.

Source and update history

  1. FDA enforcement data

    First stored snapshot of this source.

  2. FDA device-recall notice

    First stored snapshot of this source.

The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.