Ziehm Vision FD. Interventional fluoroscopic x-ray system Recall
Ziehm Vision FD. Interventional fluoroscopic x-ray system
FDA recall Class II
Ongoing
FDA lists this Class II recall for Ziehm Vision FD. Interventional fluoroscopic x-ray system. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-0576-2025
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Aug 8, 2024
- FDA report date
- Dec 11, 2024
- Quantity in commerce
- 22
- Distribution
- See key details
- FDA cause
- Radiation Control for Health and Safety Act
What is being recalled?
Ziehm Vision FD. Interventional fluoroscopic x-ray system
The retrieved code information does not contain explicit model/GTIN pairs that this publication can reliably map.
Search FDA identifier text
Search a model, catalog, lot or UDI value exactly as printed in FDA’s product description or code information.
This search checks only the FDA product description and code information displayed on this page. It does not decode a UDI, normalize GTIN lengths or establish a relationship between separately listed codes.
FDA code information
UDI: EZIEZIEHMVISIONFD1651 Serial Numbers: 93412, 93443, 93451, 93452, 93461, 93483, 93485, 93486, 93503, 93619, 93620, 93621. 93622 93623 93628 93629 93660 93661 93662 93626 93625 93627
Why was this product recalled?
Ziehm Imaging, Inc., distributor, have been informed by manufacturer, Ziehm Imaging GmbH that installed devices may not fully meet the requirements of IEC 60601-2-54 and or 21 CFR 1020.32(c) with respect to wired hand switch may fail when being exposed to mechanical stress such as shocks (e.g. dropping) or impacts can irreversibly damage the switching element in the hand switch. A defective switching element may then potentially initiate unintended radiation of the connected mobile X-ray unit.
These are potential consequences described in the source. The recall reason does not establish how many injuries or incidents occurred.
What actions did Orthoscan, Inc. take?
Ziehm Imaging, Inc. intends to notify the affected customers directly in the following manner: 1) Letter with return receipt requested, envelope, return, and reply to questionnaire, or E-mail contact. 2) Direct phone calls. Once contact is made and confirmed Ziehm Imaging Inc, shall provide replacement hand switch and instructions to the end user. Wired Hand switch 88036 Vl.02 will be requested to be returned by the customer/end user to Ziehm Imaging Inc. and will be subjected to be scrapped.
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-0576-2025
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 22, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 22, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology