8MM,FORCE BIPOLAR,IS4000 REF 471405 Recall
8MM,FORCE BIPOLAR,IS4000 REF 471405
FDA recall Class II
Ongoing
FDA lists this Class II recall for 8MM,FORCE BIPOLAR,IS4000 REF 471405. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-0883-2025
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Dec 19, 2024
- FDA report date
- Jan 22, 2025
- Quantity in commerce
- 46,759
- Distribution
- See key details
- FDA cause
- Process change control
What is being recalled?
8MM,FORCE BIPOLAR,IS4000 REF 471405
Affected model & UDI checker
Search the exact identifiers published for Z-0883-2025.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| 471405 | 8MM,FORCE BIPOLAR,IS4000 REF 471405 | Check source notice | Not specified |
| Not specified | 8MM,FORCE BIPOLAR,IS4000 REF 471405 | Check source notice | 00886874120767 |
FDA code information
Model Number: 471405 Part Number: 471405-06 UDI-DI code: 00886874120767 Batch Numbers: K10221204 K10221212 K10221218 K10230111 K10230212 K10230219 K10230226 K10230302 K10230310 K10230413 K10230420 K10230504 K10230515 K10230518 K10230525 K10230531 K10230601 K10230608 K10230615 K10230622 K10230630 K10230706 K10230713 K10230727 K10230803 K10230810 K10230817 K10230824 K10230831 K10230914 K10230928 K10231005 K10231012 K10231019 K10231027 K10231102 K10231109 K10231123 K10231130 K10231218 K10240104 K10240111 K10240118 K10240124 K10240208 K10240215 K10240219 K10240222 K10240229 K10240307 K10240327 K10240404 K10240411 K10240415 K10240418 K10240419 K10240425 K10240509 K10240516 K10240520 K10240530 K10240711 K10240728 K10240815 K10240822 K11221204 K11221212 K11221218 K11230212 K11230226 K11230302 K11230310 K11230413 K11230420 K11230515 K11230518 K11230525 K11230601 K11230608 K11230615 K11230622 K11230706 K11230713 K11230727 K11230803 K11230810 K11230914 K11231005 K11231019 K11231109 K11231116 K11240104 K11240111 K11240118 K11240208 K11240229 K11240307 K11240411 K11240418 K11240509 K11240516 K11240530 K11240711 K11240815 K11240822 K11240829 K12221204 K12221218 K12230122 K12230212 K12230226 K12230302 K12230515 K12230518 K12230525 K12230608 K12230615 K12230622 K12230706 K12230713 K12230810 K12230914 K12231109 K12240104 K12240118 K12240208 K12240229 K12240307 K12240418 K12240509 K12240530 K12240711 K12240829 K13230212 K13230226 K13230302 K13230525 K13230608 K13230706 K13230713 K13240711 K14230212 K14230226 K14230302 K14230525 K14230706 K14240711 K15230226 K15230525 K16240508 K16240530 U10230626 U10230714 U10230803 U10231201 U10231214 U10240112 U10240126 U11230803
Why was this product recalled?
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws.
What actions did Intuitive Surgical, Inc. take?
On 12/19/2024, the firm send via email an "Urgent: Medical Device Correction" Letter informing customer that Intuitive Surgical has become aware of an increase in complaints regarding frayed or broken cables on some da Vinci X and Xi reusable instruments. Customer are instructed to: 1. Customers can continue using the products in accordance with the user manual. 2. As a reminder, when using da Vinci X and Xi reusable instruments, follow the Inspection Before Use and Warnings listed in the manual provided with your system to inspect for any broken cables. Refer to Figures C and D for examples. In addition, please refer to Appendix B for additional images for detection of grip cable failures. 3. If you observe any failed (frayed or broken) grip cables prior to use, during procedure, or during reprocessing, please stop use of instrument, remove from use and inform Intuitive via the standard complaint process. 4. Inform Intuitive of any Adverse Events*/Serious Incidents** or quality problems concerning the use of the subject device via the standard complaint process. For Question and assistance - " North and South America: (800) 876-1310, Option 3 (4 am to 5 pm PST) or mail: customerservice@intusurg.com. " Europe, Middle East, Asia and Africa: +800 0821 2020 or +41 21 821 2020 (8 am to 6 pm CET) or eucs@intusurg.com " South Korea: 02-3271-3200 (9 am to 6 pm KSTJ) or support.korea@intusurg.com " Japan: 0120-56-5635 or 03-5575-1362 (9 am to 6 pm JST) or csjapan@intusurg.com " India: +1-800-103-6952 (9 am to 6 pm IT) " Taiwan: +0800-86-8181 (9 am to 6 pm CT)
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-0883-2025
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 22, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 22, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology