Medical devices, healthcare technology and the business of care
FDA RECALL RECORD · Z-0948-2026

Brand Name: AART Pectoral Implant Product Name: Pectoral Implant Recall

Brand Name: AART Pectoral Implant Product Name: Pectoral Implant Model/Catalog Number: 500-106-5 Pectoral Implant style 1 size 6 left UDI-DI code: B4905001065 500-106-6 Pectoral Implant style 1 size 6 right UDI-DI code: B4905001066 500-200-5 Pectoral Implant style 2 size 0 left UDI-DI code: B4950020205 500-200-6 500-201-5 500-201-6 500-202-5 500-202-6 500-403-5 500-403-6

FDA recall Class II

Ongoing

FDA lists this Class II recall for Brand Name: AART Pectoral Implant Product Name: Pectoral Implant. Review the affected identifiers, reported reason and manufacturer instructions below.

Recall at a glance

Recall number
Z-0948-2026
Recall classification
Class II
Enforcement status
Ongoing
Initiation date
Sep 26, 2025
FDA report date
Dec 24, 2025
Quantity in commerce
41 implants
Distribution
See key details
FDA cause
No Marketing Application

What is being recalled?

Brand Name: AART Pectoral Implant Product Name: Pectoral Implant Model/Catalog Number: 500-106-5 Pectoral Implant style 1 size 6 left UDI-DI code: B4905001065 500-106-6 Pectoral Implant style 1 size 6 right UDI-DI code: B4905001066 500-200-5 Pectoral Implant style 2 size 0 left UDI-DI code: B4950020205 500-200-6 500-201-5 500-201-6 500-202-5 500-202-6 500-403-5 500-403-6

Affected model & UDI checker

Search the exact identifiers published for Z-0948-2026.

The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.

Affected products

Model / catalog numberProductLot scope reportedUDI / GTIN
500-106-5Brand Name: AART Pectoral Implant Product Name: Pectoral ImplantCheck source noticeNot specified
500-106-6Brand Name: AART Pectoral Implant Product Name: Pectoral ImplantCheck source noticeNot specified
500-200-5Brand Name: AART Pectoral Implant Product Name: Pectoral ImplantCheck source noticeNot specified
500-200-6Brand Name: AART Pectoral Implant Product Name: Pectoral ImplantCheck source noticeNot specified
500-201-5Brand Name: AART Pectoral Implant Product Name: Pectoral ImplantCheck source noticeNot specified
500-201-6Brand Name: AART Pectoral Implant Product Name: Pectoral ImplantCheck source noticeNot specified
500-202-5Brand Name: AART Pectoral Implant Product Name: Pectoral ImplantCheck source noticeNot specified
500-202-6Brand Name: AART Pectoral Implant Product Name: Pectoral ImplantCheck source noticeNot specified
500-403-5Brand Name: AART Pectoral Implant Product Name: Pectoral ImplantCheck source noticeNot specified
500-403-6Brand Name: AART Pectoral Implant Product Name: Pectoral ImplantCheck source noticeNot specified
FDA code information

Pectoral Implant Model/Catalog Number: 500-106-5 UDI-DI code: B4905001065 Lot Number: 24-03-002 Model/Catalog Number: 500-106-6 UDI-DI code: B4905001066 Lot Number: 24-03-003 Model/Catalog Number: 500-200-5 UDI-DI code: B4905002005 Lot Numbers: 24-12-004 25-02-002 Model/Catalog Number: 500-200-6 UDI-DI code: B4905002006 Lot Numbers: 24-12-005 25-02-003 Model/Catalog Number: 500-201-5 UDI-DI code: B4905002015 Lot Numbers: 24-11-015 25-02-004 25-05-002 Model/Catalog Number: 500-201-6 UDI-DI code: B4905002016 Lot Numbers: 24-12-017 25-02-005 Model/Catalog Number: 500-202-5 UDI-DI code: B4905002025 Lot Numbers: 24-12-018 25-03-018 Model/Catalog Number: 500-202-6 UDI-DI code: B4905002026 Lot Numbers: 24-09-015 25-03-019 Model/Catalog Number: 500-403-5 UDI-DI code: B4905004035 Lot Number: 25-04-020 Model/Catalog Number: 500-403-6 UDI-DI code: B4905004036 Lot Number: 25-04-021

View the original FDA recall notice

Why was this product recalled?

Due to manufactured products that deviated from established specifications and being distributed without obtaining the required FDA premarket approvals or clearances.

What actions did DSAART LLC take?

On 09/26/2025, the firm emailed a notice to an affected customer informing them that due to identified testing issues, the firm was requesting return of gluteal implants. On 11/17/2025, the firm send an "URGENT Medical Device removal of AART Silicone Implants" Letter to customer informing them that Alpha Aesthetics is voluntarily removing products as they conduct an analysis to determine the regulatory status of the devices. Customers are instructed to: 1. Either return the affected products that have not been implanted to Alpha Aesthetics at the company's expense, or discard affected products. 2. Acknowledge their actions via the enclosed "Medical Device Return Response" letter/form. For questions or further assistance with this removal, contact ** or email **.

Read the manufacturer action recorded by FDA

Recall timeline

  1. Recall initiated by firm

  2. FDA notice posted

  3. FDA classification recorded

  4. FDA enforcement report date

Related FDA submissions

No submission number with an exact verified relationship is linked in the retrieved recall notice.

FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.

Source and update history

  1. FDA enforcement data

    First stored snapshot of this source.

  2. FDA device-recall notice

    First stored snapshot of this source.

The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.

Our data sources and methodology