ThinPrep CytoLyt Solution. Buffered Cell Wash Solution. Recall
ThinPrep¿ CytoLyt¿ Solution. Buffered Cell Wash Solution.
FDA recall Class II
Ongoing
FDA lists this Class II recall for ThinPrep CytoLyt Solution. Buffered Cell Wash Solution.. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-1093-2026
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Dec 12, 2025
- FDA report date
- Jan 21, 2026
- Quantity in commerce
- 3,728 units
- Distribution
- See key details
- FDA cause
- Under Investigation by firm
What is being recalled?
ThinPrep CytoLyt Solution. Buffered Cell Wash Solution.
Affected model & UDI checker
Search the exact identifiers published for Z-1093-2026.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| 0236004 | ThinPrep CytoLyt Solution. Buffered Cell Wash Solution. | Check source notice | 25420045508405 |
FDA code information
Catalog number: 0236004; UDI: (01)25420045508405(17)270303(10)5062EC; UDI-DI: 25420045508405; Lot number: 5062EC.
Why was this product recalled?
Fungal contamination of affected lot with Parengyodontium album.
What actions did Hologic, Inc. take?
An URGENT MEDICAL DEVICE RECALL NOTIFICATION was mailed to consignees on 12/12/25. The notification informs consignees that Hologic will provide replacement bottles of ThinPrep CytoLyt Solution to affected customers from unaffected lots based on retained sample testing. Consignees are asked to inspect their inventory for affected product and discontinue use immediately. Affected product is to be quarantined and destroyed per routine laboratory disposal procedures. Consignees are asked to complete the Customer Response Form using the provided QR Code and Hologic will coordinate replacement. Consignees can contact IQVIA MedTech for assistance with response forms at 855-620-6108 or by email at hologic-fa00286@iqvia.com. Consignees with questions about the recall notice are to contact their local Hologic Technical Support Representative.
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-1093-2026
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 20, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 20, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology