(1) Pyxis MedStation ES, Catalog No. 323; (2) Pyxis Anesthesia Station (PAS), Catalog No. 327; (3) Pyxis MedStation ES Tower, Catalog No. 352; (4) BD Pyxis CII Safe ES, Catalog No. 1116-00 Recall
(1) Pyxis MedStation ES, Catalog No. 323; (2) Pyxis Anesthesia Station (PAS), Catalog No. 327; (3) Pyxis MedStation ES Tower, Catalog No. 352; (4) BD Pyxis CII Safe ES, Catalog No. 1116-00
FDA recall Class II
Ongoing
FDA lists this Class II recall for (1) Pyxis MedStation ES, Catalog No. 323; (2) Pyxis Anesthesia Station (PAS), Catalog No. 327; (3) Pyxis MedStation ES Tower, Catalog No. 352; (4) BD Pyxis CII Safe ES, Catalog No. 1116-00. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-1119-2025
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Jan 8, 2025
- FDA report date
- Feb 19, 2025
- Quantity in commerce
- 137,741 total
- Distribution
- See key details
- FDA cause
- Software design
What is being recalled?
(1) Pyxis MedStation ES, Catalog No. 323; (2) Pyxis Anesthesia Station (PAS), Catalog No. 327; (3) Pyxis MedStation ES Tower, Catalog No. 352; (4) BD Pyxis CII Safe ES, Catalog No. 1116-00
Affected model & UDI checker
Search the exact identifiers published for Z-1119-2025.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| 323 | (1) Pyxis MedStation ES, Catalog No. 323; (2) Pyxis Anesthesia Station (PAS), Catalog No. 327; (3) Pyxis MedStation ES Tower, Catalog No. 352; (4) BD Pyxis CII Safe ES, Catalog No. 1116-00 | Check source notice | Not specified |
| 327 | (1) Pyxis MedStation ES, Catalog No. 323; (2) Pyxis Anesthesia Station (PAS), Catalog No. 327; (3) Pyxis MedStation ES Tower, Catalog No. 352; (4) BD Pyxis CII Safe ES, Catalog No. 1116-00 | Check source notice | Not specified |
| 352 | (1) Pyxis MedStation ES, Catalog No. 323; (2) Pyxis Anesthesia Station (PAS), Catalog No. 327; (3) Pyxis MedStation ES Tower, Catalog No. 352; (4) BD Pyxis CII Safe ES, Catalog No. 1116-00 | Check source notice | Not specified |
| 1116-00 | (1) Pyxis MedStation ES, Catalog No. 323; (2) Pyxis Anesthesia Station (PAS), Catalog No. 327; (3) Pyxis MedStation ES Tower, Catalog No. 352; (4) BD Pyxis CII Safe ES, Catalog No. 1116-00 | Check source notice | Not specified |
| Not specified | (1) Pyxis MedStation ES, Catalog No. 323; (2) Pyxis Anesthesia Station (PAS), Catalog No. 327; (3) Pyxis MedStation ES Tower, Catalog No. 352; (4) BD Pyxis CII Safe ES, Catalog No. 1116-00 | Check source notice | 10885403512667 |
| Not specified | (1) Pyxis MedStation ES, Catalog No. 323; (2) Pyxis Anesthesia Station (PAS), Catalog No. 327; (3) Pyxis MedStation ES Tower, Catalog No. 352; (4) BD Pyxis CII Safe ES, Catalog No. 1116-00 | Check source notice | 10885403477836 |
| Not specified | (1) Pyxis MedStation ES, Catalog No. 323; (2) Pyxis Anesthesia Station (PAS), Catalog No. 327; (3) Pyxis MedStation ES Tower, Catalog No. 352; (4) BD Pyxis CII Safe ES, Catalog No. 1116-00 | Check source notice | 10885403512674 |
| Not specified | (1) Pyxis MedStation ES, Catalog No. 323; (2) Pyxis Anesthesia Station (PAS), Catalog No. 327; (3) Pyxis MedStation ES Tower, Catalog No. 352; (4) BD Pyxis CII Safe ES, Catalog No. 1116-00 | Check source notice | 10885403512605 |
FDA code information
(1) Pyxis MedStation ES, Catalog No. 323, UDI-DI 10885403512667; (2) Pyxis Anesthesia Station (PAS), Catalog No. 327, UDI-DI 10885403477836; (3) Pyxis MedStation ES Tower, Catalog No. 352, UDI-DI 10885403512674; (4) BD Pyxis CII Safe ES, Catalog No. 1116-00, UDI-DI 10885403512605; All Serial Numbers; Software Versions v1.10 and prior Affected
Why was this product recalled?
Software issues could potentially result in: 1) delays in accessing dispensing software application, 2) wrong therapy (dose, item, timing, etc.), or 3) unauthorized access and/or compliance related issues
These are potential consequences described in the source. The recall reason does not establish how many injuries or incidents occurred.
What actions did CareFusion 303, Inc. take?
On January 8, 2025, the firm notified customers via email and mailed letter titled "Urgent Medical Device Correction". Firm states customers can continue to use Pyxis products in accordance with their labeling and any previously provided field action notifications, including the following guidance: 1. Facilities should establish policies and procedures for when an automated dispensing system is unavailable. 2. Device Keys can manually access unavailable drawers, but must be readily available and retrievable to adequately mitigate the risk. 3. Emergency supplies should be physically available in care areas for critical or urgent medications. 4. If using critical override mode to access contents of the device, users must use extra precautions and verify correct medications are selected. The firm anticipates releasing software update ES 1.11 beginning June 2025, which will address these software issues.
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-1119-2025
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 22, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 22, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology