Medica Capillary Tubes; EasyBloodGas/EasyStat Capillary Tube Kit. Recall
Medica Capillary Tubes; EasyBloodGas/EasyStat Capillary Tube Kit.
FDA recall Class II
Ongoing
FDA lists this Class II recall for Medica Capillary Tubes; EasyBloodGas/EasyStat Capillary Tube Kit.. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-1370-2026
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Dec 31, 2025
- FDA report date
- Feb 25, 2026
- Quantity in commerce
- 1,578 units
- Distribution
- See key details
- FDA cause
- Nonconforming Material/Component
What is being recalled?
Medica Capillary Tubes; EasyBloodGas/EasyStat Capillary Tube Kit.
Affected model & UDI checker
Search the exact identifiers published for Z-1370-2026.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| 7303 | Medica Capillary Tubes; EasyBloodGas/EasyStat Capillary Tube Kit. | Check source notice | Not specified |
| Not specified | Medica Capillary Tubes; EasyBloodGas/EasyStat Capillary Tube Kit. | Check source notice | 00840095607575 |
FDA code information
Model No. 7303, UDI-DI: 00840095607575, Lot No. 25XXX.
Why was this product recalled?
A systematic positive bias of up to 20% was identified across the reportable potassium range, resulting in false elevation results of patient samples when using Medica s capillary tubes.
What actions did Medica Corporation take?
An URGENT FIELD SAFETY NOTICE was sent to consignees on 01/09/25 informing them that potassium results obtained using affected devices in capillary mode may be falsely elevated. The FSN instructed consignees not to report potassium results obtained in capillary mode using affected lots on the Easy Stat Analyzer. The FSN is to be forwarded to end users and to where product was further distributed. Consignees are to contact their local representative with any questions.
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-1370-2026
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 21, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 21, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology