Brand Name: Hitachi Proton Beam Therapy System Ref: PROBEAT-FR Recall
Brand Name: Hitachi Proton Beam Therapy System Ref: PROBEAT-FR
FDA recall Class II
Ongoing
FDA lists this Class II recall for Brand Name: Hitachi Proton Beam Therapy System Ref: PROBEAT-FR. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-1429-2026
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Feb 6, 2026
- FDA report date
- Mar 4, 2026
- Quantity in commerce
- 1
- Distribution
- See key details
- FDA cause
- Software design
What is being recalled?
Brand Name: Hitachi Proton Beam Therapy System Ref: PROBEAT-FR
Affected model & UDI checker
Search the exact identifiers published for Z-1429-2026.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| Not specified | Brand Name: Hitachi Proton Beam Therapy System Ref: PROBEAT-FR | Check source notice | 04560333350204 |
FDA code information
Serial number: PTFR-01/ UDI:(01)04560333350204(11)240112(21)PTFR-01
Why was this product recalled?
Software anomaly in the patient positioning system may result in positional discrepancy.
These are potential consequences described in the source. The recall reason does not establish how many injuries or incidents occurred.
What actions did Hitachi, Ltd. Radiation Oncology Systems, Kashiwanoha take?
Between the dates of February 5-11, 2026, Hitachi, Ltd, issued an "URGENT: MEDICAL DEVICE RECALL" notification dated January 21, 2026, via Service Team Manager to affected consignees. Hitachi is asking consignees to take the following actions: 1. Until the PPS software has been updated with the corrected version, users are instructed to follow the System Operation instruction in the document. 2. Users are also asked to post the document in a prominent space and sign its cover. 3. Complete and return the acknowledgment and receipt form. Action by the firm: Hitachi plans to update the PPS software to a corrected version that prevents the mismatch between the commanded error correction parameter and the internal variable. starting in late March 2026 and the users will be contacted after the update. If you have any questions, please call QA Manager at Tel: (408) 986-6300. Monday through Friday, 8:00 AM to 5:00 PM, Central Time.
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-1429-2026
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 21, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 21, 2026
- FDA enforcement data
First stored snapshot of this source.