Beckman Coulter DxI 9000 Access Immunoassay Analyzer Recall
Beckman Coulter DxI 9000 Access Immunoassay Analyzer
FDA recall Class II
Ongoing
FDA lists this Class II recall for Beckman Coulter DxI 9000 Access Immunoassay Analyzer. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-1664-2025
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Mar 27, 2025
- FDA report date
- Apr 30, 2025
- Quantity in commerce
- 370 units
- Distribution
- See key details
- FDA cause
- Software design
What is being recalled?
Beckman Coulter DxI 9000 Access Immunoassay Analyzer
Affected model & UDI checker
Search the exact identifiers published for Z-1664-2025.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| Not specified | Beckman Coulter DxI 9000 Access Immunoassay Analyzer | Check source notice | 15099590732103 |
FDA code information
UDI/DI 15099590732103, all units run with system software versions SW 1.20.0 and below
Why was this product recalled?
When DxI 9000 Access Immunoassay Analyzer is connected to a host system (laboratory information system (LIS) or middleware) and has accumulated canceled QC test results that were not sent by LIS, the analyzer may lose communication with the host system. The lost connection interrupts sample processing, which delays reporting patient test results and may subsequently delay patient treatment.
What actions did BECKMAN COULTER, INC. take?
Beckman Coulter issued an URGENT MEDICAL DEVICE RECALL notice to its consignees on 03/27/2025 via USPS first class mail. The notice explained the issue with the device, impact to the patient, and provided a workaround until a software upgrade is available. If the consignee further distributed the affected device, they were directed to provide a copy of the notice to the recipient. For questions, contact Customer Support Center, from the website: http://www.beckmancoulter.com
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-1664-2025
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 22, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 22, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.