Artix MT Thrombectomy Device, REF: 32-102 Recall
Artix MT Thrombectomy Device, REF: 32-102
FDA recall Class II
Ongoing
FDA lists this Class II recall for Artix MT Thrombectomy Device, REF: 32-102. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-1728-2025
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Apr 8, 2025
- FDA report date
- May 14, 2025
- Quantity in commerce
- 45
- Distribution
- See key details
- FDA cause
- Labeling Change Control
What is being recalled?
Artix MT Thrombectomy Device, REF: 32-102
Affected model & UDI checker
Search the exact identifiers published for Z-1728-2025.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| 32-102 | Artix MT Thrombectomy Device, REF: 32-102 | Check source notice | Not specified |
| Not specified | Artix MT Thrombectomy Device, REF: 32-102 | Check source notice | 00810123710584 |
FDA code information
UDI-DI: 00810123710584, Lot: 24100082, Expiration: 14 April 2025. IFU: IU-01087 Rev. B
Why was this product recalled?
Thrombectomy device specifies vessel range of 2.5-6 mm on the pouch, carton, and Instructions for Use rather than the correct vessel range of 3-6 mm, which could incrementally increase the radial force on the artery, which has the potential of vascular complications.
These are potential consequences described in the source. The recall reason does not establish how many injuries or incidents occurred.
What actions did Inari Medical - Oak Canyon take?
On 4/8/2025, correction and removal notices were distributed to customers who were asked to do the following: 1) Review notice and the accompanying copy of the device IFU (IU-01087 Rev. C) and disseminate it to any applicable personnel and device users at your facility and network to ensure they are aware of the unused device replacement. 2) Notice should be shared with any organization where affected devices may have been transferred. 3) Complete and return the acknowledgement reply form via email to If you have any questions, please contact your local sales representative, or the firm's Customer Service at 877-923-4747, or Quality department at QA@inarimedical.com.
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-1728-2025
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 22, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 22, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology