Medical devices, healthcare technology and the business of care
FDA RECALL RECORD · Z-1773-2026

XTANT MEDICAL Xpress Pedicle Screw System Dual Lead 6.5 x 50 mm, Part Number X073-6555-DL. Recall

XTANT MEDICAL Xpress Pedicle Screw System Dual Lead 6.5 x 50 mm, Part Number X073-6555-DL.

FDA recall Class II

Ongoing

FDA lists this Class II recall for XTANT MEDICAL Xpress Pedicle Screw System Dual Lead 6.5 x 50 mm, Part Number X073-6555-DL.. Review the affected identifiers, reported reason and manufacturer instructions below.

Recall at a glance

Recall number
Z-1773-2026
Recall classification
Class II
Enforcement status
Ongoing
Initiation date
Feb 18, 2026
FDA report date
Apr 15, 2026
Quantity in commerce
2 units
Distribution
See key details
FDA cause
Under Investigation by firm

What is being recalled?

XTANT MEDICAL Xpress Pedicle Screw System Dual Lead 6.5 x 50 mm, Part Number X073-6555-DL.

The retrieved code information does not contain explicit model/GTIN pairs that this publication can reliably map.

Search FDA identifier text

Search a model, catalog, lot or UDI value exactly as printed in FDA’s product description or code information.

This search checks only the FDA product description and code information displayed on this page. It does not decode a UDI, normalize GTIN lengths or establish a relationship between separately listed codes.

FDA code information

UDI/DI M697X0736555DL1, Lot Number 4375-01

View the original FDA recall notice

Why was this product recalled?

Units from one lot were mislabeled with an incorrect part number, identifying the device as a shorter screw length than it physically is.

What actions did Xtant Medical Holdings, Inc. take?

Xtant Medical issued an URGENT: MEDICAL DEVICE CORRECTION notice to its consignee on 2/18/2026 via FedEx. The notice explained the reason for the correction, risk to health, and requested the following: 1. Review all devices from Lot 4375-01, including devices in loose stock and devices staged in implant trays or caddies, and verify device identification using the laser-etched markings on each implant to confirm that devices are stored or staged in the appropriate location consistent with their size and configuration. 2. If any device retains non-conforming labeling, relabel the device and discard of the incorrect label and application of the corrected labeling provided by Xtant Medical. 3. No product return is required unless a device cannot be confidently verified or corrected on site; please contact Xtant Medical for further guidance in such cases. 4. Complete Correction Acknowledgement to confirm completion of the above actions. For questions, Rebecca Lennemann, SVP, Quality & Regulatory Affairs, at 1-406-924-5878, Monday through Friday, 8 a.m. to 5 p.m. (Mountain Time).

Read the manufacturer action recorded by FDA

Recall timeline

  1. Recall initiated by firm

  2. FDA notice posted

  3. FDA classification recorded

  4. FDA enforcement report date

Related FDA submissions

No submission number with an exact verified relationship is linked in the retrieved recall notice.

FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.

Source and update history

  1. FDA enforcement data

    First stored snapshot of this source.

  2. FDA device-recall notice

    First stored snapshot of this source.

The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.

Our data sources and methodology