Custom Convenience Kits Pre Op Kit - NS, Part Number AMS14994 Recall
Custom Convenience Kits Pre Op Kit - NS, Part Number AMS14994
FDA recall Class II
Ongoing
FDA lists this Class II recall for Custom Convenience Kits Pre Op Kit - NS, Part Number AMS14994. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-1920-2026
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Mar 11, 2026
- FDA report date
- Apr 29, 2026
- Quantity in commerce
- 380 units
- Distribution
- See key details
- FDA cause
- Process control
What is being recalled?
Custom Convenience Kits Pre Op Kit - NS, Part Number AMS14994
The retrieved code information does not contain explicit model/GTIN pairs that this publication can reliably map.
Search FDA identifier text
Search a model, catalog, lot or UDI value exactly as printed in FDA’s product description or code information.
This search checks only the FDA product description and code information displayed on this page. It does not decode a UDI, normalize GTIN lengths or establish a relationship between separately listed codes.
FDA code information
UDI-DI: B098AMS149940; Lot Numbers: 220039 221423 224226 224793 225009
Why was this product recalled?
The product correction was initiated because B Braun is issuing a voluntary Urgent Medical Device Correction for gravity IV administration sets as well as pump administration sets utilized with BBMI s Infusomat Space Large Volume Pump, Outlook Pump and Vista Basic Pump due to potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers or other connections and the ability to prime (occlusion).
These are potential consequences described in the source. The recall reason does not establish how many injuries or incidents occurred.
What actions did Windstone Medical Packaging, Inc. take?
An URGENT: MEDICAL DEVICE CORRECTION notification letter was sent to customers on 3/11/26. AMS requests that you undertake the following activities: 1. Review your inventory for the affected kits, all lots are impacted. 2. Communicate the notification with all personnel that utilize B Braun Admin. Sets contained within AMS kits. 3. If you have further distributed this product, please identify your distribution partners, and notify them at once of the product notification. Your notification to your customers should include a copy of this notification letter. 4. Please complete and return the AMS Urgent Medical Device Product Notification Response Required form within 5 business days and return via email to fieldcorrectiveaction@alignedmedical.com even if you have no affected product on hand. Please complete the attached AMS Urgent Medical Device Product Notification Response Required form and return it to Aligned Medical Solutions at the Fax number provided on the form. If you do not have the affected product, you must complete and return the form. If you have any questions or concerns, please do not hesitate to contact us at fieldcorrectiveaction@alignedmedicalsolutions.com.
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-1920-2026
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 21, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 21, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology