Jewel Precision Reusable Rigid Sterilization Container System. Recall
Jewel Precision Reusable Rigid Sterilization Container System. Model Number: JP-24-8.
FDA recall Class II
Ongoing
FDA lists this Class II recall for Jewel Precision Reusable Rigid Sterilization Container System.. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-2033-2025
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- May 23, 2025
- FDA report date
- Jul 2, 2025
- Quantity in commerce
- 1
- Distribution
- See key details
- FDA cause
- No Marketing Application
What is being recalled?
Jewel Precision Reusable Rigid Sterilization Container System. Model Number: JP-24-8.
Affected model & UDI checker
Search the exact identifiers published for Z-2033-2025.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| JP-24-8 | Jewel Precision Reusable Rigid Sterilization Container System. | Check source notice | Not specified |
| Not specified | Jewel Precision Reusable Rigid Sterilization Container System. | Check source notice | 00850043393139 |
FDA code information
Model No JP-24-8. GTIN: 00850043393139. Lot Number: 16899
Why was this product recalled?
The 8-inch model of the Jewel Precision Reusable Rigid Sterilization Container System (i.e., model number: JP-24-8) was not cleared by the FDA. The letter to file justifying the change in size was insufficient.
What actions did Jewel Precision Sheet Metal & Machining Co, Inc. take?
Jewel Precision sent a "MEDICAL DEVICE RECALL" letter dated 5/23/2025 to the single consignee on 05/23/2025 via email. The consignee was instructed to; review all stock and inventory, return the product to Jewel Precision for destruction, complete the Acknowledgement and Receipt form on pages 3-4 of the letter indicating the actions taken and approval of completion, in the event that the product has been scrapped, please provide evidence of scrapping it and certification that the product has been destroyed by the customer. As per the customer's purchase order, the piece was to be used for testing purposes only. For products that have been shipped to your customers, identify and notify your customers of the recall, requesting return; obtain their acknowledgement and approval that the part has been shipped back. Action by company: discontinued the product. For questions email: jsitler@jewelprecision.com or call 973-857-5545 x19.
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-2033-2025
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 22, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 22, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology