Surgify Halo, 5.4 mm, Long Recall
Surgify Halo, 5.4 mm, Long, Model/Catalog Number: 54.125.NVG.U1; drills, burrs, trephines & accessories (simple, powered)
FDA recall Class II
Ongoing
FDA lists this Class II recall for Surgify Halo, 5.4 mm, Long. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-2571-2026
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Apr 30, 2026
- FDA report date
- Jul 1, 2026
- Quantity in commerce
- N/A
- Distribution
- See key details
- FDA cause
- Under Investigation by firm
What is being recalled?
Surgify Halo, 5.4 mm, Long, Model/Catalog Number: 54.125.NVG.U1; drills, burrs, trephines & accessories (simple, powered)
Affected model & UDI checker
Search the exact identifiers published for Z-2571-2026.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| 54.125.NVG.U1 | Surgify Halo, 5.4 mm, Long | Check source notice | Not specified |
| Not specified | Surgify Halo, 5.4 mm, Long | Check source notice | 06429811532304 |
FDA code information
UDI: 06429811532304 ; All lots until the IFU update has been implemented
Why was this product recalled?
Potential for burr breakage, occurring during bi-portal endoscopic spinal surgery (BESS).
These are potential consequences described in the source. The recall reason does not establish how many injuries or incidents occurred.
What actions did SURGIFY MEDICAL OY take?
Surgify issued a Medical Device Correction Notice - Surgify Halo - Restriction of Use notice to its consignees on 4/30/2026 via email. The notice explained the issue, potential risk, and requested the following: "What steps must the user take? Please review your current practice and ensure the device is only used in accordance with the updated safety information. Instruction to Customers: The customers have been instructed to do the following: - Do not use this device in endoscopic surgical procedures. If endoscopic access is required, an alternative instrument should be selected. Specifically: . Do not use this device in endoscopic surgical procedures. If endoscopic access is required, an alternative instrument should be selected. . Ensure that all relevant clinical staff and surgical team members are made aware of this notice. . Please retain this notice for your records and attach it to the relevant product documentation. Please acknowledge receipt of this Medical Device Correction Notice by replying to raqa@surgifymedical.com within 30 business days, confirming that the notice has been read, understood, and communicated to all relevant users within your organization. Please include your facility name, your name, and your role. If you have previously used the device in endoscopic procedures without incident, no patient follow-up is required; however, this application should now be discontinued in line with the updated safety information." For questions regarding this matter, please contact us by phone at +358 105 176 310 or via email at support@surgifymedical.com.
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
| Product / regulatory record | Company | Pathway | Decision date | Source |
|---|---|---|---|---|
| SURGIFY MEDICAL OY | 510(k) clearance | Mar 26, 2026 | FDA |
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-2571-2026
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 21, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 21, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology