ARTIS icono ceiling. Recall
ARTIS icono ceiling. Model Number: 11328100.
FDA recall Class II
Ongoing
FDA lists this Class II recall for ARTIS icono ceiling.. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-2642-2026
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- May 20, 2026
- FDA report date
- Jul 8, 2026
- Quantity in commerce
- 119 units
- Distribution
- See key details
- FDA cause
- Software design
What is being recalled?
ARTIS icono ceiling. Model Number: 11328100.
Affected model & UDI checker
Search the exact identifiers published for Z-2642-2026.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| 11328100 | ARTIS icono ceiling. | Check source notice | Not specified |
| Not specified | ARTIS icono ceiling. | Check source notice | 4056869295923 |
FDA code information
Model Number: 11328100. UDI-DI: 4056869295923. Serial Numbers: 194180, 194184, 194169, 194101, 194131, 194223, 194193, 194216, 194215, 194080, 194186, 194164, 194102, 194054, 194181, 194185, 194194, 194188, 194095, 194094, 194093, 194090, 194086, 194203, 194037, 194116, 194114, 194207, 194209, 194120, 194177, 194036, 194038, 194213, 194103, 194190, 194096, 194139, 194165, 194066, 194210, 194098, 194221, 194072, 194047, 194212, 194226, 194197, 194141, 194039, 194088, 194204, 194113, 194222, 194083, 194128, 194219, 194146, 194145, 194099, 194205, 194200, 194081, 194082, 194218, 194147, 194189, 194109, 194183, 194187, 194105, 194119, 194201, 194050, 194049, 194174, 194199, 194079, 194135, 194085, 194125, 194034, 194121, 194111, 194158, 194092, 194133, 194220, 194192, 194071, 194136, 194182, 194161, 194162, 194211, 194127, 194126, 194124, 194123, 194122, 194108, 194175, 194035, 194225, 194149, 194107, 194208, 194104, 194089, 194227, 194041, 194040, 194173, 194179, 194163, 194172, 194143, 194117, 194144.
Why was this product recalled?
Potential for loss of movement capability after adjusting the detector lift height to its maximum or minimum limits.
These are potential consequences described in the source. The recall reason does not establish how many injuries or incidents occurred.
What actions did Siemens Medical Solutions USA, Inc. take?
Siemens notified consignees on about 05/19/2026 via letter. Consignees were instructed to ensure all users of the affected products within each organization and others who may need to be informed will receive the relevant safety information provided within the notice and comply with the recommendations therein, maintain the recall notification with product related records and until the corrective measures have been completed. Siemens will be releasing a software update to correct the issue via an Update Instruction AX018/26/S. All affected systems will be corrected by Siemens Healthineers. The service organization will contact consignees in the near future to arrange a date to perform the corrective action. Additionally, consignees were instructed to confirm and acknowledge receipt of the recall notification digitally.
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-2642-2026
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 21, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 21, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology