Novarad NovaPACS is documented as a networked computer system for routing and archiving diagnostic medical images. The June 2026 DICOM Conformance Statement applies to NovaPACS Version 9.x and describes receiving DICOM objects for permanent storage, retrieving information about those objects, and a retrieval mechanism for the images. Vendor web pages position the product within a broader enterprise imaging product range that includes radiology, cardiology, pathology, mammography, and encounter-based imaging. The Diagnostic Viewer manual describes display, manipulation, archiving, and evaluation functions for radiologists, physicians, technologists, clinicians, and nurses. [1][2][3][5]
DICOM Storage and Communication Scope
The DICOM Conformance Statement identifies NovaPACS as a self-contained networked computer system used for routing and archiving diagnostic medical images. It receives DICOM objects from external systems for permanent storage, allows retrieval of information about those images, and provides a retrieval mechanism for the images themselves. The document states that the system conforms to the DICOM Standard, while also noting that the conformance statement alone is not guaranteed to ensure desired interoperability or successful interconnectivity. [1]
The conformance statement lists supported storage SOP classes for X-ray, digital mammography, digital intra-oral X-ray, multi-frame grayscale secondary capture, and ECG waveform storage. It also documents Modality Worklist Information Model FIND, Storage Commitment Push Model, and Patient Root, Study Root, and Patient/Study Only Query/Retrieve FIND and MOVE functions. The document states that relational queries are not supported either as an SCU or SCP. [1]
The revision history records changes for NovaPACS 9.x, including an expanded SOP Class list, updated transfer syntaxes, removal of Explicit VR Big Endian, addition of JPEG-LS Lossless and JPEG-LS Lossy entries, and removal of retired Hardcopy and Stored Print SOP Classes. The NOVARAD-SERVER Application Entity is described as listening for incoming DICOM connections on port 104. [1]
Enterprise Imaging Configuration
Novarad's marketing pages describe NovaPACS EI as an advanced PACS system with enterprise imaging built in. The vendor states that it allows facilities to perform radiology, cardiology, pathology, and mammography, with a framework and tools for encounter-based imaging captured throughout the hospital or system. The same pages state that the system scales from large hospitals down to a Critical Access Hospital. [2][3][6]
Vendor materials describe a patient-centric Universal Viewer that enables the EMR and is said to provide the right information at the right time for more accurate diagnoses, assist in value-based care, and enhance doctor-patient engagement through storyboards. The vendor also claims the solution improves multi-specialty and cross-department collaboration, leading to better operational efficiencies and cost management. These are vendor claims rather than independently documented clinical outcomes. [2][3][4]
The marketing pages list highlighted features including a web-deployed viewer, complete customization, intelligent routing, service level agreements, single-click Nova 3D+, 2-click tool access with a radius menu, and worklist management. They also state that NovaPACS EI is evergreen, with upgrades included at no charge, and that disaster recovery is always included. The vendor describes a US-based, 24/7 support team. [2][3][4]
Implementation Boundaries and Documentation Gaps
The DICOM Conformance Statement states that the document is intended for hospital staff, health system integrators, software designers, or implementers, and assumes the reader has a working understanding of DICOM. It also states that the conformance statement should be read in conjunction with the DICOM Standard, but by itself is not guaranteed to ensure the desired interoperability and a successful interconnectivity. The document notes that interactions between a Novarad viewer and server are proprietary for performance and functionality reasons. [1]
The public documents do not specify pricing, deployment timelines, supported operating system versions beyond the mention of Windows 11 as a registered trademark, or quantitative performance benchmarks. The viewer manual revision history records improvements to the authentication process and enhancements to the Search filter in version 9.1.5, and enhancements to Fluency Direct in version 9.1.6. The documents do not provide independent clinical validation of the vendor's claims about diagnostic accuracy, readmission reduction, or operational efficiency. [5][7]
Viewer and Workflow Functions
The Diagnostic Viewer manual describes the product as allowing end users to display, manipulate, archive, and evaluate images. It identifies intended users as radiologists, physicians, technologists, clinicians, and nurses. The manual states that mobile devices are not intended to replace a full workstation and should be used only when there is no access to a workstation. It also states that mobile devices are not to be used for mammography or fMRI. [5]
The manual documents a Web Viewer as a thin-client version that downloads Image Viewer files temporarily and is accessed through a secure server using the Internet. It states that users must download and use Microsoft's .NET Framework 4 Client Profile to use the Web Viewer from the Novaweb page. The manual also describes MPR view, which reconstructs an axial plane into sagittal and coronal planes, and notes that Novarad provides MIP/MPR integration and support. [5][7]
Documented viewer functions include annotation options that can be added to any image, including in Cine view, and a Research option that launches GlobalRad, described as a database for cases with similar anatomical or pathological findings. The manual states that the Research option can help with more accurate diagnoses and more efficient research, though it does not provide comparative evidence for that claim. [7]
Reporting and RIS Integration
The Diagnostic Viewer manual describes an Exam Report function that allows users to see the report associated with the patient file if one exists. It states that Exam Reports are only available if the system is integrated with Nova RIS. When reports are finalized in Nova RIS, a DICOM PDF report is sent to NovaPACS and added to the study as a new series. If no matching NovaPACS study is found, a placeholder study is created for the report. [5]
The manual states that administrators must locate the placeholder study in the NovaPACS Admin Console on the Studies tab and move the report series to the correct study manually. It also notes that PDF reports can be viewed but not edited, while authorized users can edit HTML reports. The Documents function allows users to see documents associated with the patient file that were scanned into the RIS. [5]
The vendor's enterprise imaging pages describe a Radiology Information System Workflow Module, Nova RIS, with multi-modality scheduling, electronic forms, management reports, turnaround time reports, HL7 integration, clinical decision support, voice recognition, NPI integration, and an optional billing module. These descriptions appear in marketing materials and do not constitute a formal product specification. [6]
Specialty Workflow Modules
Novarad's marketing pages describe several specialty workflow modules within the enterprise imaging ecosystem. NovaMG PRO is described as an integrated mammography viewer with customized viewing sequences for hyper efficient workflows. NovaCardio is described as a full cardiology suite covering motion cardiac imaging, structured reporting, EKG, CTA, cardiac ultrasound, MRI, and angio, with quick comparison of priors. [6]
The vendor also describes NovaOrtho as a complete orthopedic PACS with orthopedic templating, storyboarding, measurement tools for specialized viewing, and preoperative planning. Additional described modules include wound care workflow for capturing wound care related imaging, emergency department workflow for visible light images and videos, and CryptoChart for sharing patient medical images and records through a QR or secure web access code. [6]
The marketing pages state that the enterprise imaging system provides viewer and management functions for all medical images, including those created in radiology and cardiology as well as visible light images captured throughout the rest of the hospital. They also state that the system supports MPR, image fusion, AI, and 3D, on-premises or cloud options, remote reading, all modalities in a single viewer, and up to five monitor configurations. These are vendor descriptions without independent verification in the public documents. [6]