TS Misc. Instruments Tray, Triathlon. Recall
TS Misc. Instruments Tray, Triathlon. Catalog Number: 6543-6-519.
FDA recall Class II
Ongoing
FDA lists this Class II recall for TS Misc. Instruments Tray, Triathlon.. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-0167-2027
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Sep 16, 2026
- FDA report date
- Oct 21, 2026
- Quantity in commerce
- 577 trays
- Distribution
- See key details
- FDA cause
- Labeling design
What is being recalled?
TS Misc. Instruments Tray, Triathlon. Catalog Number: 6543-6-519.
Affected model & UDI checker
Search the exact identifiers published for Z-0167-2027.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| 6543-6-519. | TS Misc. Instruments Tray, Triathlon. | Check source notice | 07613327555127 |
| 6543-6-519 | TS Misc. Instruments Tray, Triathlon. | Check source notice | Not specified |
FDA code information
Catalog Number: 6543-6-519. GTIN: 07613327555127. All lot numbers used prior to the correction date of May 8, 2026 are impacted.
Why was this product recalled?
Reprocessing instructions provided in LSTPI-B specify a sterilization dry time of 30 minutes for the trays sterilized in blue wrap. When blue wrap is used, the 30-minute dry time may lead to a small amount of residual moisture remaining after sterilization.
What actions did HOWMEDICA OSTEONICS CORP take?
Stryker notified consignees on about 09/16/2026 via "MEDICAL DEVICE CORRECTION" letter mailed through UPS 2-day air. Consignees were informed that reprocessing instructions provided in LSTPI-B specify a sterilization dry time of 30 minutes, however, these trays require a sterilization dry time of 40 minutes when sterilized in blue wrap. Consignees were instructed to inform users of the Medical Device Correction and forward the notice to all individuals who need to be made aware or organizations who have consigned product, review and follow the updated instructions provided in LSTPI-B Cleaning, Sterilization, Inspection, and Maintenance of Reusable Medical Devices Reference Guide, complete and return the provided Medical Device Correction Business Reply Form.
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-0167-2027
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 19, 2026
- openFDA device recall record · Source release Nov 14, 2026 · Retrieved Nov 19, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.