FDA enforcement records list Philips North America as the recalling firm for multiple Class II device recalls, with filing addresses in Cambridge, Massachusetts, and report dates spanning October and November 2026. The records describe MR software and upgrade products, a wireless access point, and a device identified only by model number. Each entry is a separate enforcement record with its own recall number, product quantity and stated reason for recall. [1][2][3]
MR software and upgrade filings
Three enforcement records concern magnetic resonance products. Evolution upgrade 1.5T and Evolution upgrade 3.0T cover model numbers 782116, 782148, 782166 and 782201 for 1.5T systems and 782117, 782143 and 782162 for 3.0T systems, across software versions R11, R12 and R13. Upgrade dStream covers model 782127 with a stated quantity of one unit. Ingenia Blue Seal SE and Blue Seal XE cover models 782185 and 782192, with a stated quantity of six units. [3][4][5]
The dStream and Blue Seal records share a stated reason: diffusion tensor imaging scans exported in Enhanced MR DICOM format contain incorrect diffusion directions, which affects third-party tractography processing. Both records carry a recall initiation date of 20260828 and a center classification date of 20260925, and both list worldwide distribution. [4][5]
Wireless connectivity record
Philips Smart-hopping 2.0 AP 1.4 GHz, model 867216, is the subject of a record stating a quantity of 174 units and US nationwide distribution. The stated reason is unreliable wireless roaming behavior of Smart-hopping 1.0 wireless clients during transport when connecting to Smart-hopping 2.0 infrastructure, resulting in loss of connectivity to the central monitoring system (PIC iX). The record lists a recall initiation date of 20260916 and a center classification date of 20261016. [2]
Model 712010 and filing scope
One record identifies the product only as model 712010, with a stated quantity of 563 units and worldwide distribution to US nationwide and international locations. The stated reason is a potential for the device to fail immediately after an exposure, causing the system to remain stationary. The record carries a report date of 20261104. [1]
An FDA recall search filtered to firm Philips and recall dates from 09/01/2026 to 11/02/2026 returns 45 results, and a separate search page shows establishment registration entries naming Philips North America. These counts describe the supplied search results as of the retrieval date and are not measures of total company sales, total portfolio or safety performance. [9][7]